{rfName}
Mi

Indexado en

Licencia y uso

Altmetrics

Grant support

This work was funded with support of the Erasmus+ Programme of the European Union (Framework Agreement number: 2013-0040). This publication reflects the views only of the author, and the Commission cannot be held responsible for any use that may be made of the information contained therein. Additionally, the research leading to these results has received funding partially from 'la Caixa' Foundation; Cerebra Foundation for the Brain Injured Child (Carmarthen, Wales, UK); AGAUR 2014 SGR grant No. 928 and 'la Secretaria d'Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya (A.P: 2014DI083)'.

Análisis de autorías institucional

Baños NAutor (correspondencia)Murillo-Bravo CAutor o CoautorMigliorelli FAutor o CoautorPerez-Moreno AAutor o CoautorRios JAutor o CoautorGratacos EAutor o CoautorPalacio MAutor o Coautor

Compartir

9 de junio de 2017
Publicaciones
>
Artículo
No

Mid-trimester sonographic Cervical Consistency Index to predict spontaneous preterm birth in a low-risk population.

Publicado en:Ultrasound In Obstetrics & Gynecology. 51 (5): 629-636 - 2018-05-01 51(5), DOI: 10.1002/uog.17482

Autores: Banos, N; Murillo-Bravo, C; Julia, C; Migliorelli, F; Perez-Moreno, A; Rios, J; Gratacos, E; Valentin, L; Palacio, M

Afiliaciones

Ctr Biomed Res Rare Dis CIBER ER, Barcelona, Spain      CIBERER    CIBER - Centro de Investigacion Biomedica en Red       - Autor o Coautor
Hosp Clin Barcelona, IDIBAPS, Med Stat Core Facil, Barcelona, Spain      Hospital Clinic de Barcelona    IDIBAPS    University of Barcelona - Autor o Coautor
Lund Univ, Lund, Sweden      Lund University - Autor o Coautor
Skane Univ Hosp, Malmo, Sweden      Lund University    Skane University Hospital - Autor o Coautor
Transmural Biotech SL, Barcelona, Spain - Autor o Coautor
Univ Autonoma Barcelona, Lab Biostat & Epidemiol, Barcelona, Spain      Autonomous University of Barcelona - Autor o Coautor
Univ Barcelona, Fetal I D Fetal Med Res Ctr, BCNatal Barcelona Ctr Maternal Fetal & Neonatal M, Hosp Clin, Sabino de Arana 1, E-08028 Barcelona, Spain.      University of Barcelona    Hospital Clinic de Barcelona - Autor o Coautor
Univ Barcelona, Hosp Clin, Ctr Maternal Fetal & Neonatal Med, Fetal I D Fetal Med Res Ctr,BCNatal Barcelona, Barcelona, Spain      Hospital Clinic de Barcelona    University of Barcelona - Autor o Coautor
Univ Barcelona, Hosp St Joan de Deu, Inst Clin Ginecol Obstet & Neonatol, Inst Invest Biomed August Pi i Sunyer, Barcelona, Spain      IDIBAPS    University of Barcelona    Hospital Clinic de Barcelona - Autor o Coautor
Univ Barcelona, IDIBAPS, Hosp St Joan de Deu, Sabino de Arana 1, E-08028 Barcelona, Spain.      Hospital Clinic de Barcelona    University of Barcelona    IDIBAPS - Autor o Coautor
Ver más

Resumen

To investigate the effectiveness of mid-trimester sonographic cervical consistency index (CCI) for the prediction of spontaneous preterm birth (sPTB) in low-risk pregnancies and to compare its performance with that of mid-trimester sonographic cervical-length (CL) measurement.This was a prospective cohort study of women with a singleton pregnancy examined by ultrasound at 19?+?0 to 24?+?6?weeks' gestation. All women underwent transvaginal ultrasound examination of the cervix, but CCI and CL were measured, offline, only in women without a risk factor for sPTB. Staff and participants were blinded to CL and CCI results. CCI was obtained by calculating the ratio between the anteroposterior diameter of the uterine cervix at maximum compression and at rest. The primary outcome was prediction of sPTB before 37?+?0?weeks. Receiver-operating characteristics (ROC) curves were produced and sensitivity and specificity were calculated for the optimal cut-off based on the ROC curve and for the 1st , 5th and 10th centiles of CCI and CL. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to estimate intra- and interobserver agreement and reliability for measurement of CCI and CL.Of the 749 women who underwent ultrasound examination of the cervix, 532 were included for analysis. The rates of sPTB before 37?+?0 and before 34?+?0?weeks were 4.1% (22/532) and 1.3% (7/532), respectively. The rates of short cervix ?0.90 both for CCI and CL, while interobserver ICC was 0.89 for CCI and 0.90 for CL.Second-trimester CCI is a better predictor of sPTB

Palabras clave

cervical consistency indexcervical-length measurementscervix uterilengthpessarypregnancyprogesteronespontaneous preterm birthultrasonographyAdultCervical consistency indexCervical length measurementCervical-length measurementsCervix uteriFemaleGestational ageHumansPregnancyPregnancy trimester, secondPremature birthProspective studiesReference standardsReproducibility of resultsRisk factorsRoc curveSingle-blind methodSpontaneous preterm birthUltrasonographyWomen

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista Ultrasound In Obstetrics & Gynecology debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia WoS (JCR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2018, se encontraba en la posición 3/83, consiguiendo con ello situarse como revista Q1 (Primer Cuartil), en la categoría Obstetrics & Gynecology. Destacable, igualmente, el hecho de que la Revista está posicionada por encima del Percentil 90.

Desde una perspectiva relativa, y atendiendo al indicador del impacto normalizado calculado a partir de las Citas Mundiales proporcionadas por WoS (ESI, Clarivate), arroja un valor para la normalización de citas relativas a la tasa de citación esperada de: 1.04. Esto indica que, de manera comparada con trabajos en la misma disciplina y en el mismo año de publicación, lo ubica como trabajo citado por encima de la media. (fuente consultada: ESI 14 Nov 2024)

Esta información viene reforzada por otros indicadores del mismo tipo, que aunque dinámicos en el tiempo y dependientes del conjunto de citaciones medias mundiales en el momento de su cálculo, coinciden en posicionar en algún momento al trabajo, entre el 50% más citados dentro de su temática:

  • Field Citation Ratio (FCR) de la fuente Dimensions: 7.77 (fuente consultada: Dimensions Jul 2025)

De manera concreta y atendiendo a las diferentes agencias de indexación, el trabajo ha acumulado, hasta la fecha 2025-07-18, el siguiente número de citas:

  • WoS: 19
  • Scopus: 17
  • Europe PMC: 9

Impacto y visibilidad social

Desde la dimensión de Influencia o adopción social, y tomando como base las métricas asociadas a las menciones e interacciones proporcionadas por agencias especializadas en el cálculo de las denominadas “Métricas Alternativas o Sociales”, podemos destacar a fecha 2025-07-18:

  • El uso, desde el ámbito académico evidenciado por el indicador de la agencia Altmetric referido como agregaciones realizadas por el gestor bibliográfico personal Mendeley, nos da un total de: 80.
  • La utilización de esta aportación en marcadores, bifurcaciones de código, añadidos a listas de favoritos para una lectura recurrente, así como visualizaciones generales, indica que alguien está usando la publicación como base de su trabajo actual. Esto puede ser un indicador destacado de futuras citas más formales y académicas. Tal afirmación es avalada por el resultado del indicador “Capture” que arroja un total de: 84 (PlumX).

Con una intencionalidad más de divulgación y orientada a audiencias más generales podemos observar otras puntuaciones más globales como:

  • El Score total de Altmetric: 0.75.
  • El número de menciones en la red social Facebook: 1 (Altmetric).
  • El número de menciones en la red social X (antes Twitter): 1 (Altmetric).

Análisis de liderazgo de los autores institucionales

Este trabajo se ha realizado con colaboración internacional, concretamente con investigadores de: Sweden.

Existe un liderazgo significativo ya que algunos de los autores pertenecientes a la institución aparecen como primer o último firmante, se puede apreciar en el detalle: Primer Autor (Baños López, Núria) y Último Autor (Palacio Riera, Montserrat).

el autor responsable de establecer las labores de correspondencia ha sido Baños López, Núria.