{rfName}
Ab

Indexat a

Llicència i ús

Altmetrics

Anàlisi d'autories institucional

Brugaletta SAutor (correspondència)Valdes MAutor o coautorSabate MAutor o coautor

Compartir

12 d’abril de 2016
Publicacions
>
Article
No

Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-Year results of a propensity score matching comparison: the BVS-examination study (Bioresorbable Vascular Scaffold-a clinical

Publicat a:Jacc-Cardiovascular Interventions. 8 (1): 189-197 - 2015-01-01 8(1), DOI: 10.1016/j.jcin.2014.10.005

Autors: Brugaletta, Salvatore; Gori, Tommaso; Low, Adrian F; Tousek, Petr; Pinar, Eduardo; Gomez-Lara, Josep; Scalone, Giancarla; Schulz, Eberhard; Chan, Mark Y; Kocka, Viktor; Hurtado, Jose; Gomez-Hospital, Juan Antoni; Muenzel, Thomas; Lee, Chi-Hang; Cequier, Angel; Valdes, Mariano; Widimsky, Petr; Serruys, Patrick W; Sabate, Manel

Afiliacions

Bellvitge Hosp, Inst Cardiol, Barcelona, Spain      University of Barcelona    Catalan Health Institute    Bellvitge University Hospital - Autor o coautor
Charles Univ Prague, Univ Hosp Kralovske Vinohrady, Cardio Ctr, Prague, Czech Republic      University Hospital Vinohrady    Charles University Prague - Autor o coautor
Erasmus Univ, Med Ctr, Thoraxctr, Rotterdam, Netherlands      Erasmus University Rotterdam - Autor o coautor
Hosp Clin Barcelona, Thorax Inst, Dept Cardiol, C-Villarroel 170, E-08036 Barcelona, Spain.      Hospital Clinic de Barcelona    University of Barcelona - Autor o coautor
Med Klin & Poliklin Kardiol Angiol & Innere Inten, Mainz, Germany - Autor o coautor
Natl Univ Hlth Syst, Natl Univ Heart Ctr Singapore, Dept Cardiac, Singapore, Singapore      National University of Singapore - Autor o coautor
Univ Barcelona, Hosp Clin Barcelona, Thorax Inst, Inst dInvest Biomed August Pi Sunyer, Barcelona, Spain      University of Barcelona    Hospital Clinic de Barcelona    IDIBAPS       - Autor o coautor
Virgen Arrixaca Hosp, Dept Cardiol, Intervent Cardiol Unit, Murcia, Spain      Hospital Clinico Universitario Virgen de la Arrixaca - Autor o coautor
Veure més

Resum

The purpose of this study was to compare the 1-year outcome between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic stent (EES) in ST-segment elevation myocardial infarction (STEMI) patients.The Absorb BVS (Abbott Vascular, Santa Clara, California) is a polymeric scaffold approved for treatment of stable coronary lesions. Limited and not randomized data are available on its use in ST-segment elevation myocardial infarction (STEMI) patients.This study included 290 consecutive STEMI patients treated by BVS, compared with either 290 STEMI patients treated with EES or 290 STEMI patients treated with bare-metal stents (BMS) from the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-segment Elevation Myocardial Infarction) trial, by applying propensity score matching. The primary endpoint was a device-oriented endpoint (DOCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization, at 1-year follow-up. Device thrombosis, according to the Academic Research Consortium criteria, was also evaluated.The cumulative incidence of DOCE did not differ between the BVS and EES or BMS groups either at 30 days (3.1% vs. 2.4%, hazard ratio [HR]: 1.31 [95% confidence interval (CI): 0.48 to 3.52], p = 0.593; vs. 2.8%, HR: 1.15 [95% CI: 0.44 to 2.30], p = 0.776, respectively) or at 1 year (4.1% vs. 4.1%, HR: 0.99 [95% CI: 0.23 to 4.32], p = 0.994; vs. 5.9%, HR: 0.50 [95% CI: 0.13 to 1.88], p = 0.306, respectively). Definite/probable BVS thrombosis rate was numerically higher either at 30 days (2.1% vs. 0.3%, p = 0.059; vs. 1.0%, p = 0.324, respectively) or at 1 year (2.4% vs. 1.4%, p = 0.948; vs. 1.7%, p = 0.825, respectively), as compared with EES or BMS.At 1-year follow-up, STEMI patients treated with BVS showed similar rates of DOCE compared with STEMI patients treated with EES or BMS, although rate of scaffolds thrombosis, mostly clustered in the early phase, was not negligible. Larger studies with longer follow-up are needed to confirm our findings.Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Paraules clau

absorbartery-diseasedesigneverolimus-eluting stentimplantationmetaanalysisoutcomesrationalestemisystemthrombosistrialAbsorbAbsorbable implantsAdultAdverse effectsAgedAnalogs and derivativesArticleBare metal stentBiodegradable implantBiodegradable polymerBioresorbable vascular stentCardiovascular agentCardiovascular agentsClinical trialComparative studyControlled clinical trialControlled studyCoronary thrombosisDatabases, factualDevicesDrug eluting coronary stentDrug eluting stentDrug-eluting stentsEverolimusEverolimus-eluting stentFactual databaseFemaleFollow upHeart deathHeart infarctionHumanHumansKaplan meier methodKaplan-meier estimateLogistic modelsMajor clinical studyMaleMetalMetalsMiddle agedMortalityMulticenter studyMyocardial infarctionPercutaneous coronary interventionPriority journalPropensity scoreProportional hazards modelProportional hazards modelsProsthesisProsthesis designRapamycinRecurrenceRecurrent diseaseRetrospective studiesRetrospective studyRevascularizationRisk factorRisk factorsSirolimusSt segment elevation myocardial infarctionStatistical modelStemiStent thrombosisTimeTime factorsTreatment outcome

Indicis de qualitat

Impacte bibliomètric. Anàlisi de la contribució i canal de difusió

El treball ha estat publicat a la revista Jacc-Cardiovascular Interventions a causa de la seva progressió i el bon impacte que ha aconseguit en els últims anys, segons l'agència WoS (JCR), s'ha convertit en una referència en el seu camp. A l'any de publicació del treball, 2015, es trobava a la posició 7/124, aconseguint així situar-se com a revista Q1 (Primer Cuartil), en la categoria Cardiac & Cardiovascular Systems.

Des d'una perspectiva relativa, i tenint en compte l'indicador de impacte normalitzat calculat a partir de les Citacions Mundials proporcionades per WoS (ESI, Clarivate), proporciona un valor per a la normalització de citacions relatives a la taxa de citació esperada de: 4.87. Això indica que, comparat amb treballs en la mateixa disciplina i en el mateix any de publicació, el situa com un treball citat per sobre de la mitjana. (font consultada: ESI 14 Nov 2024)

Aquesta informació es reforça amb altres indicadors del mateix tipus, que encara que dinàmics en el temps i dependents del conjunt de citacions mitjanes mundials en el moment del seu càlcul, coincideixen a posicionar en algun moment el treball, entre el 50% més citats dins de la seva temàtica:

  • Mitjana Ponderada de l'Impacte Normalitzat de l'agència Scopus: 4.88 (font consultada: FECYT Febr 2024)
  • Field Citation Ratio (FCR) de la font Dimensions: 44.81 (font consultada: Dimensions Jul 2025)

Concretament, i atenent a les diferents agències d'indexació, aquest treball ha acumulat, fins a la data 2025-07-05, el següent nombre de cites:

  • WoS: 158
  • Scopus: 145
  • Europe PMC: 87
  • Google Scholar: 137

Impacte i visibilitat social

Des de la dimensió d'influència o adopció social, i prenent com a base les mètriques associades a les mencions i interaccions proporcionades per agències especialitzades en el càlcul de les denominades "Mètriques Alternatives o Socials", podem destacar a data 2025-07-05:

  • L'ús, des de l'àmbit acadèmic evidenciat per l'indicador de l'agència Altmetric referit com a agregacions realitzades pel gestor bibliogràfic personal Mendeley, ens dona un total de: 94.
  • L'ús d'aquesta aportació en marcadors, bifurcacions de codi, afegits a llistes de favorits per a una lectura recurrent, així com visualitzacions generals, indica que algú està fent servir la publicació com a base del seu treball actual. Això pot ser un indicador destacat de futures cites més formals i acadèmiques. Aquesta afirmació està avalada pel resultat de l'indicador "Capture", que aporta un total de: 101 (PlumX).

Amb una intenció més de divulgació i orientada a audiències més generals, podem observar altres puntuacions més globals com:

  • El Puntuació total de Altmetric: 0.5.
  • El nombre de mencions a la xarxa social Facebook: 1 (Altmetric).
  • El nombre de mencions a la xarxa social X (abans Twitter): 1 (Altmetric).

Anàlisi del lideratge dels autors institucionals

Aquest treball s'ha realitzat amb col·laboració internacional, concretament amb investigadors de: Czech Republic; Germany; Netherlands; Singapore.

Hi ha un lideratge significatiu, ja que alguns dels autors pertanyents a la institució apareixen com a primer o últim signant, es pot apreciar en el detall: Primer Autor (Brugaletta, Salvatore) i Últim Autor (Sabaté Tenas, Manel).

l'autor responsable d'establir les tasques de correspondència ha estat Brugaletta, Salvatore.